                                                 Ratnagiri





        APC Reduction for Vacuum Pump




        How  and  why was  the  problem                         checked  for  such  type  of  deviation.

        identified?                                             However,       team      has     carried     out
                                                                brainstorming & why-why analysis to find
        Vacuum Pump plays an important role in
                                                                out all causes deviations. This kind of
        power plant. It is used for removal of
                                                                problem of valve plate damage was not
        non-condensible         gases      from      the
                                                                occurred earlier, hence after replacement
        condenser.
                                                                of valve plate, the pump stable operation
        In U #3, it was observed that Vacuum
                                                                is one of the challenge.
        Pump - A was taking more current with low
        vacuum than vacuum Pump-B & it is                       Impact of solution to the business?

        resulting into high APC. The Vacuum
                                                                By replacing the damaged valve plate the
        pump-A current was 167 Ampere
                                                                power, saving is occurred & this resulted in
        (A) & Vacuum Pump-B current was-157
                                                                reduction in the plant APC, improvement in
        Ampere (A).
                                                                vacuum and moral boost up of the team.
        How was the problem solved?
                                                                           Team Members
        The discharge side valve plate (Teflon
        plate) at both ends was observed                          Mr. Tushar Pande

        damaged  &  it  is  causing  recirculation  &             Mr. C. Thangakan

        back pressure with high current. The                      Mr. Arun Paul
        damaged valve plates were replaced with                   Mr. Chinmay Thakur
        new one. The pump trial taken & observed                  Mr. Shakeer Ahmed

        reduction in pump current from 167 A to                   Mr. Gokul Kalaskar

        157 A.

        What were the challenges

        encountered?


        To find out the exact root cause is
        a big challenge in vacuum pump
        system.        Normally       suction

        strainer, glands & cooler are





                                                                                                                   19